Voltage regulation in commercial establishments
Voltage regulation and power factor justification are very much interdependent, especially in commercial establishments. In most cases, it can be a very costly affair to obtain voltage regulation.
One of the best solutions to obtain voltage regulation is to employ large or parallel conductors in the circuit. This will help reduce voltage drop when larger loads are in operation.
How can power factor contribute to this?
- It helps improve voltage
- It lowers energy costs
- It helps conductors to be more energy efficient
- Transformers, buses, over current devices, conductors and switches, can all be utilized to their full capacities. This will in turn reduce the core investment as well as annual costs involved
Now that we have understood the importance of voltage regulation and power factor justification, let us now understand their importance individually.
Voltage Regulation
A good voltage regulation controls the voltage of an entire system, so that it stays within the specified limits, and is safe to work within all kinds loads specified by the manufacturer.In other words, a good voltage regulation, sees to it that all the electrical equipment within the defined circuit, are supplied with the voltage that is almost equivalent to their individual designer needs and specifications.
Voltage regulation in terms of percentage (in any circuit), can be expressed as:
Voltage Regulation (%) = ((No load voltage – full load voltage) X 100) / (no load voltage)
Following are the factors that affect voltage regulation:
- Wires and cable size
- Wires and cable type
- Raceway type
- Transformer’s reactance
- Transformer cables
- Means of starting a motor
- Design of the circuit
- Power factor
- Loading means
- Loading degree
Note: Voltage regulators are normally employed in circuits where voltage regulation is not possible by changing the size of the conductor. Voltage regulators can both be automatic as well as manual, and come in varying sizes and shapes.
Depending on your requirement, you may choose a voltage regulator that suits your individual computer, or an your entire database organization, if you have one :)
Power Factor Correction
Let us say, you have installed a new load (e.g., a heavy load genset) in your commercial apartment, and it has resulted in a poor power factor. What will you do?Well, in such cases, you generally perform power factor correction.
This correction often requires installation of some extra capacitors in the circuit, which can be an expensive affair. Hence, it is recommended that a proper evaluation is made (with the help of professionals) before installing large equipment in your buildings such as, refrigeration systems, central air conditioning systems, etc.
This evaluation helps in determining if an economic alternative, such as a synchronous motor can help serve the purpose. If installing a synchronous motor can help achieve power factor correction, it will be a cheap and durable alternative.
Power factor can be expressed as:
PF = P/S ≥ 0.95
‘PF’ is the Power Factor;
‘P’ is the real power measured in Watts;
‘S’ is the apparent power measured in Volt-Amperes.
Neglecting poor power factor (if, PF<0 .9="" a="" also="" and="" attract="" because="" bills="" building="" but="" circuit="" department="" draws="" electricity="" enormously="" factor="" from="" in="" increase="" mains.="" may="" more="" not="" only="" p="" penalties="" poor="" power="" supply="" the="" this="" with="" your="">
Conclusion
And the expenses incurred in installing a suitable voltage regulator and getting the power factor checked, will generally be returned to you in the form of better equipment performance, durability and electricity savings, within a year.0>