Audio Frequency Transformer - LEKULE

Breaking

19 Sept 2015

Audio Frequency Transformer

Audio-frequency transformers are used mainly for matching impedances and transmitting audio frequencies. They also provide isolation from direct currents and present balanced impedances to lines or circuits.
Types of Magnetic Cores
       The magnetic core for this type of transformer is usually an EI or EE type using either audio-grade silicon steel or nickel-alloy tape cores in toroidal form are used for extreme bandwidths. High permeability ferrite cores with highly polished mating surfaces are also used to obtain wide bandwidths.
       If there is no direct current in the windings, it is possible to design a small, high quality audio transformer with a high permeability ferrite core. Material with initial permeability above 10 000 is available. To minimize the air gap in the assembled core, the mating surfaces are ground flat and polished to a mirror finish. Because of the small core volume, when these transformers are used at low frequencies care must be taken to avoid core saturation. The maximum flux density in a core is given by:
Bmax  =  (3.49 x 106) E/fNAc
where,
       Bmax  = maximum flux density (gauss),
       E = rms volts,
       f = frequency (hertz),
      N = number of winding turns,
      Ac = cross section of core (square inches)
Design of Audio-Frequency Transformers
Important parameters - Important parameters are generator and load impedances, Rs and Rl, respectively; generator voltage ; frequency band to be transmitted; harmonic distortion; and operating voltages (for adequate insulation).
Midband Frequencies - The relative low- and high-frequency responses are taken with reference to midband frequencies where
      α Eout/Eg  =   [( 1 + Rs/Rl) + Rl/a2 Rl]-1
Low Frequencies - At low frequencies, the equivalent unity-ratio network of a transformer becomes approximately as shown in Fig. 1.
Fig.1 Equivalent network of an audio frequency transformer at low frequencies
       Amplitude =  [( 1 + (R'par/Xm)2 ]-1/2
       Phase angle = tan-1 (R'par/Xm)
where,
       R'par = (R1 R2 a2 ) / (R1 + R2 a2 )
       R1 = Rg + Rp
       R2 = Rl + Rs
       Xm = 2Ï€fLp
       In a good output transformer, Rp , Rs and Rc may be neglected. In input or interstage transformers, Rc may be omitted.


High Frequencies - At high frequencies, neglecting the effect of winding and other capacitances, the equivalent unity-ratio network becomes approximately as in Fig. 2.

Fig. 2 Equivalent network of an audio frequency transformer at high frequencies, neglecting the effect of the winding shunt capacitances 
       Amplitude =   [1 + (Xl/R'se)]-1/2
       Phase angle = tan-1 (Xl/R'se)
       where,
       R'se = R1 +  R2 a2 ,
       Xl = 2 Ï€f l scp   ,
       l scp = inductance measured across primary with secondary short-circuited = l p +  a2l s.
       The low- and high-frequency responses are shown by the curves of Fig. 3.
Fig. 3 Universal frequency and phase response characteristics of output transformers.
       If at high frequencies the effect of winding and other capacitances is appreciable, the equivalent network on a 1:1 turns-ratio basis becomes as shown in Fig. 4.
Fig. 4  Equivalent network of a 1:1 turns ratio audio frequency transformer at high frequencies when effect of winding shunt capacitances is apprecaible

In a step-up transformer, C2 = equivalent shunt capacitances of both windings. In a step-down transformer, C2 shunts both leakage inductances and R2. The relative high-frequency response of this network is given by
       This high-frequency response is plotted in Fig. 5 for R2 = R1 (matched impedances), based on simplified equivalent networks as indicated. At frequency fr Xl = Xc and B = Xc/Rl.
Fig. 5 Transformer characteristics at high frequencies for matched impedances
Harmonic Distortion - Harmonic distortion requirements may a constitute a deciding factor in the design of transformers. Such distortion is causffed by either variations in load impedance or non linearity of magnetizing current. The percent harmonic voltage appearing in the output of a loaded transformer is given by
(Percent harmonics = 100Eh/Ef = 100Ih /If ( R'par/Xm)   [ 1 - (R'par/4Xm) ]
       where 100Ih/If = percent of harmonic current measured with a zero-impedance source (values in table 1 are for a 4-percent silicon-steel core).
Table 1 Harmonics by various flux densities B in a 4-percent silicon-steel-core audio trasformer
Insertion Loss - Insertion loss is the loss introduced into the circuit by addition of the transformer. At midband, the loss is caused by winding resistance and core loss. Frequency discrimination adds to this at low and high frequencies. Insertion loss is input divided by output expressed in decibels, or (in terms of measured voltages and imepdance)
(dB insertion loss) = 10 log [ (Eg2 R1) / (4Eo2 Rg ) ]
Impedance Match - For maximum power transfer, the reflected load impedance should equal the generator impedance. Winding resistance should be included in the is calculation: For matching
       Rg  = a2 ( R1 + Rs) +  Rp
       Also, in a properly matched transformer
       Rg  = a2 R1 = (Zoc  x Zsc)1/2
where,
       Zoc  = transformer primary open-circuit impedance,
       Zsc = transformer primary impedance with secondary winding short-circuited.
       If more than one secondary is used, the turns ratio to match impedances properly depends on the power delivered from each winding.
       Ns/Np  = [ (Ra/Rg) (Wa/Wp) ]1/2
Example : Using Fig. 6
       N2/Np  = [(10/600)(10/16)]1/2 = 0.102
       N3/Np  = [(50/600)(5/16)]1/2 = 0.161
       N4/Np  = [ (100/600)(1/16)]1/2 = 0.102

Fig. 6  Multisecodary audio trasformer