A demonstration of filter inductor design for boost converters, design of the coupled inductor for a two-output forward converter, and the design of flyback transformer in continuous conduction mode.
The filter inductor in the converter circuit is operated in a small B-H loop region as compared to the wide region for the conventional transformer. The area of B-H loop is proportional to the total current ripple in the inductor. The core losses are negligible, according to the minor B-H loop area. On the other hand, copper loss depends on the DC current flowing through inductor. The same curve is also applicable in the case of coupled inductor. Design is majorly constrained by the copper loss and the saturation condition of the filter inductor.
Figure 1. B-H Loop for Filter Inductor
Figure 2. B-H loop for the Conventional Transformer
Design of an Inductor for Boost Converter
The circuit diagram of the boost converter with related waveform under CCM:
Figure 3. Circuit of Boost Converter
We should know the requirements for this converter circuit according to the following given specifications:
VS, VO, f, PO
Where,
VS = Input Voltage
VO = Output Voltage
f = Operating frequency in kHz. (f=1T)
PO = Output power in kW
We can get the duty ratio of the boost converter by this equation:
The input DC current of the converter is the inductor current which is given by this equation:
We have seen earlier that,
Thus,
Also,
Thus, the required inductance value from Equations 1 and 2 is given by
R.M.S value of the inductor current in the case of a triangular wave is given by the following expression:
R.M.S value of voltage across inductor is given by
Figure 4. Supply Current, Diode Current, Inductor Current and Inductor Voltage respectively (Boost Converter)
We will then get the required final volume of the core. We can now also multiply the volume with the corresponding power density of the material at a particular frequency to measure core loss. Power density is measured by the plot between the power density at a particular frequency and the change in the magnetic flux density given by the manufacturer. Change in flux density is given by:
We can neglect the core loss if it is comparatively less than the copper loss, and use the material which has higher core loss and high saturation flux density. This leads to a smaller size inductor core.
Design of a Coupled Inductor for a Two-Output Forward Converter
Coupled inductors have multiple windings
wound on the same core for high value of inductance in common mode
current while low value of inductance for the differential mode current.
Coupled inductors have lower leakage inductance and AC current losses.
Consider a coupled inductor as shown in the figure below:
Figure 5. Coupled Inductor
The number of turns for L1and L2 must be same to maintain the volt-time balance condition. Magnetizing field is produced by the sum of the currents i.e. i1+i2 which flows through the core. Leakage field is produced by the difference of the currents i.e. i1-i2 which flows through air. The circuit diagram for the two-output forward converter using coupled inductor is given below.
Figure 6. Circuit for the Two-Output Forward Converter
Common Mode Current,
Differential Mode Current,
These currents both contribute in the eddy current losses.
Common Mode Inductance,
Differential Mode Inductance,
Here, Pis the permeance provided by the
manufacturer and R is the reluctance. For common mode current, coupled
inductors act like two inductors L1and L2 in
parallel. For differential mode, coupled inductors act like a
transformer. There is a considerable DC component in the current flowing
through L1and L2 which causes the net magnetization of the core.
Similar design procedure with the single-winding filter inductor is used.
Design of a Flyback Transformer in CCM
The flyback transformer acts as an
inductor, having two windings where only one of its windings carries the
current at a particular time. The flyback transformer stores the energy
and releases it later, which requires an air gap. As both the windings
carry the current alternatively even with the continuous total
ampere-turns, high AC winding losses are associated with the flyback
converter irrespective of its operating mode. Core loss depends on the
magnetizing current Im for the transformer and is usually significant in the case of the discontinuous conduction mode.
In CCM, conversion ratio for the converter is:
For the desired duty cycle and nominal supply voltage, the initially expected turns ratio is given by:
where vo' is the sum of the
voltages across the load, switch, rectifier and copper loss referred to
the secondary side. We even need to see the duty ratio for the
worst-case current of the DC and AC components. Duty cycle and turns
ratio can be possibly altered to optimize the design. We can select the
particular material according to the proper specifications with the help
of the data sheet.
Figure 7. Circuit for Flyback Converter
Core loss is negligible and flux density
is restricted by the saturation of the core. Net field in the core is
the sum of the magnetizing current and the leakage field. Magnetizing
field is used for the storage of energy and basically acts as an
inductor while the leakage field performs like a transformer.
Change in Magnetic flux density can obtained by
Here, Isc is the short-circuit current which produces the maximum flux density.
The number of turns on the secondary side is given by
Thus, the corresponding turns for the
secondary can be calculated. Select the core shape and its type using
the guide provided by the manufacturer. Based on that, we need to
calculate the thermal resistance, conductor size, air gap length,
winding loss, DC and AC losses consequently.
Figure 8. Waveforms of Input Voltage, Output Voltage, Magnetizing Current, and Diode Current for the Flyback Converter
No comments: